Lexus ES: Generator Inverter Stuck On (P0A7A9E,P1C5F19)

DTC SUMMARY

MALFUNCTION DESCRIPTION

This DTC indicates that a large current flowed in the inverter generator. The cause of this malfunction may be one of the following:

Area

Main Malfunction Description

Hybrid vehicle transaxle assembly

  • Open or short circuit in the generator coils
  • Generator (MG1) internal malfunction (iron particles or damage from foreign objects)

Resolver

Open or short circuit in the generator resolver

Inverter

  • Inverter internal circuit malfunction
  • Malfunction in ECU that controls the inverter
  • Inverter control sensor (current sensor, VH sensor, VL sensor)

Inverter cooling system

  • Inverter water pump assembly malfunction
  • Coolant leak
  • Coolant frozen
  • Blockage

DESCRIPTION

For a description of the inverter.

Click here

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

P0A7A9E

Generator Inverter Stuck On

Generator inverter fail signal detected (circuit malfunction)

(1 trip detection logic)

  • Inverter cooling system
  • Cooling fan system
  • Grille shutter system
  • Wire harness or connector
  • Motor cable
  • Hybrid vehicle transaxle assembly
  • PCU fuse
  • Inverter with converter assembly
  • Hybrid vehicle control ECU

Comes on

Master Warning Light:

Comes on

P1C5F19

Generator Inverter Circuit Current Above Threshold

Generator inverter fail signal detected:

A malfunction is detected in any of the generator components (generator inverter, Generator (MG1), generator resolver, motor generator control ECU, etc.).

(1 trip detection logic)

  • Inverter cooling system
  • Cooling fan system
  • Grille shutter system
  • Wire harness or connector
  • Motor cable
  • Hybrid vehicle transaxle assembly
  • PCU fuse
  • Inverter with converter assembly
  • Hybrid vehicle control ECU

Comes on

Master Warning Light:

Comes on

Related Data List

DTC No.

Data List

P0A7A9E

P1C5F19

Emergency Shutdown Signal

MONITOR DESCRIPTION

If too much current is detected flowing through the generator inverter, the generator inverter transmits an inverter fail signal to the motor generator control ECU. Upon receiving this signal, the motor generator control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY

Related DTCs

P0A7A (INF P0A7A9E): GFIV detection (Circuit malfunction)

P1C5F (INF P1C5F19): GFIV detection (Over current malfunction)

Required sensors/components

Generator inverter

Frequency of operation

Continuous

Duration

TMC's intellectual property

MIL operation

1 driving cycle

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not stored

TMC's intellectual property

Other conditions belong to TMC's intellectual property

-

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property

-

COMPONENT OPERATING RANGE

Motor generator control ECU

DTC P0A7A (INF P0A7A9E) is not detected

DTC P1C5F (INF P1C5F19) is not detected

CONFIRMATION DRIVING PATTERN

HINT:

  • After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

    Click here

  • When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.

    Click here

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 2 minutes or more.
  5. Turn the power switch on (IG) and turn the Techstream on.
  6. With power switch on (IG) and wait for 5 seconds or more. [*1]
  7. Turn the power switch on (READY) and wait for 5 seconds or more. [*2]
  8. Drive the vehicle approximately 10 minutes mainly using the engine. [*3]

    NOTICE:

    As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.

    HINT:

    [*1] to [*3]: Normal judgment procedure.

    The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.

  9. Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
  10. Check the DTC judgment result.

    HINT:

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.

WIRING DIAGRAM

Refer to the wiring diagram for the Generator Resolver Circuit.

Click here

Refer to the wiring diagram for the Motor Resolver Circuit.

Click here

Refer to the wiring diagram for the Generator High-voltage Circuit.

Click here

Refer to the wiring diagram for the Motor High-voltage Circuit.

Click here

Refer to the wiring diagram for the Inverter Low-voltage Circuit.

Click here

Refer to the wiring diagram for the Cooling System.

Click here

CAUTION / NOTICE / HINT

CAUTION:

  • Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
    • Inspecting the high-voltage system
    • Disconnecting the low voltage connector of the inverter with converter assembly
    • Disconnecting the low voltage connector of the HV battery
  • To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
  • After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here

    HINT:

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

    *a

    Without waiting for 10 minutes

NOTICE:

  • After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

    Click here

  • After troubleshooting and repairing all output DTCs, be sure to replace the inverter with converter assembly. (The inverter with converter assembly may have been broken or damaged due to overheating.)

PROCEDURE

1.

CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL)

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.

(d) Check for DTCs.

Powertrain > Motor Generator > Trouble Codes

Result

Proceed to

P0A7A73 is not output.

A

P0A7A73 is also output.

B

NOTICE:

  • If P0A7A73 is output, troubleshoot it first. After completing the troubleshooting for P0A7A73, perform troubleshooting for this DTC.
  • Parts repaired or replaced during troubleshooting for P0A7A73 do not need to be re-inspected in this diagnostic procedure.

(e) Turn the power switch off.

B

GO TO STEP 3

A

2.

CHECK DTC OUTPUT

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / Hybrid Control, Motor Generator and HV Battery / Trouble Codes.

(d) Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble Codes Powertrain > HV Battery > Trouble Codes

Result

Proceed to

P0A7A9E or P1C5F19 only is output, or DTCs except the ones in the table below are also output.

A

DTCs of hybrid control system in the tables below are output.

B

DTCs of motor generator control system in the tables below are output.

C

DTCs of hybrid battery control system in the tables below are output.

D

Table 1

Malfunction Content

System

Relevant DTC

Insulation Malfunction

Hybrid control system

P1C7C49

Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure

P1C7D49

Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure

P1C7E49

Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure

P1C7F49

Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure

System Main Relay or High Voltage Circuit Malfunction

Hybrid control system

P0AD911

Hybrid/EV Battery Positive Contactor Circuit Short to Ground

P0AD915

Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open

P0ADD11

Hybrid/EV Battery Negative Contactor Circuit Short to Ground

P0ADD15

Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open

P1C8449

High Voltage Power Resource Circuit Short during Ready ON

HV Battery Malfunction

Hybrid battery control system

P060629

Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid

P060687

Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message

P060A47

Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure

P060A87

Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message

P060B16

Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold

P060B49

Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure

P0ABF11

Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground

P0ABF15

Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open

P0ABF28

Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure

P0ABF2A

Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range

P0B0E11

Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground

P0B0E15

Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open

P0B1362

Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure

P0E2D00

Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance

P1A001C

Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range

P1A6017

Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold

P1A6116

Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold

P1A8100

Hybrid/EV Battery Stack 1 Delta SOC High (Extreme)

P1A8600

Hybrid/EV Battery Stack 2 Delta SOC High (Extreme)

P1AC413

Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open

P1AC49E

Hybrid/EV Battery Stack 1 Current Interrupt Device Stuck On

P1AC513

Hybrid/EV Battery Stack 2 Current Interrupt Device Circuit Open

P1AC59E

Hybrid/EV Battery Stack 2 Current Interrupt Device Stuck On

P1AFD00

Flying Capacitor Circuit Voltage Out of Range

P1AFD1C

Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range

P1CBB12

Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery

P1CBB14

Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open

P1CC81E

Hybrid/EV Battery Stack 1 Voltage Difference Out of Range

P1CC91E

Hybrid/EV Battery Stack 2 Voltage Difference Out of Range

P301A1C

Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range

P31AA17

Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold

P31AB16

Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold

P31B300

Hybrid/EV Battery Voltage High

P33DA1E

Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range

P33DB1E

Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range

P33E01B

Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold

P33E11B

Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold

P33EC16

(Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold

P33ED16

(Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold

U115087

Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message

Hybrid control system

P0A1F94

Hybrid/EV Battery Energy Control Module Unexpected Operation

P0ABF00

Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance

P0B231C

Hybrid/EV Battery "A" Voltage Sensor Circuit Voltage Out of Range

U011187

Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message

U117587

Lost Communication with Hybrid/EV Battery Energy Control Module "A" (Powertrain Bus) Missing Message

Table 2

Malfunction Content

System

Relevant DTC

Microcomputer malfunction

Motor generator control system

P0A1A47

Generator Control Module Watchdog / Safety μC Failure

P0A1A49

Generator Control Module Internal Electronic Failure

P0A1B1F

Generator Control Module Circuit Intermittent

P1C2A1C

Generator A/D Converter Circuit Circuit Voltage Out of Range

P1C2A49

Generator A/D Converter Circuit Internal Electronic Failure

P1C2B1C

Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range

P1C2B49

Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure

P313383

Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect

P313386

Communication Error from Generator to Drive Motor "A" Signal Invalid

P313387

Communication Error from Generator to Drive Motor "A" Missing Message

P313483

Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect

P313486

Communication Error from Drive Motor "A" to Generator Signal Invalid

P313487

Communication Error from Drive Motor "A" to Generator Missing Message

Hybrid control system

P0A1B49

Drive Motor "A" Control Module Internal Electronic Failure

Power source circuit malfunction

Motor generator control system

P06B01C

Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range

P06D61C

Generator Control Module Offset Power Circuit Voltage Out of Range

Communication malfunction

Motor generator control system

P312487

Lost Communication between Drive Motor "A" and HV ECU Missing Message

Hybrid control system

P312387

Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message

Sensor and actuator circuit malfunction

Motor generator control system

P0A3F16

Drive Motor "A" Position Sensor Circuit Voltage Below Threshold

P0A3F21

Drive Motor "A" Position Sensor Signal Amplitude < Minimum

P0A3F22

Drive Motor "A" Position Sensor Signal Amplitude > Maximum

P0A4B16

Generator Position Sensor Circuit Voltage Below Threshold

P0A4B21

Generator Position Sensor Signal Amplitude < Minimum

P0A4B22

Generator Position Sensor Signal Amplitude > Maximum

P0A6012

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery

P0A6014

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open

P0A601C

Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range

P0A6312

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery

P0A6314

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open

P0A631C

Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range

P0BE512

Drive Motor "A" Phase U Current Sensor Circuit Short to Battery

P0BE514

Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open

P0BE528

Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0BE912

Drive Motor "A" Phase V Current Sensor Circuit Short to Battery

P0BE914

Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open

P0BE928

Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0BED12

Drive Motor "A" Phase W Current Sensor Circuit Short to Battery

P0BED14

Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open

P0BED28

Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0BFD62

Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure

P0C5013

Drive Motor "A" Position Sensor Circuit "A" Circuit Open

P0C5016

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold

P0C5017

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold

P0C5A13

Drive Motor "A" Position Sensor Circuit "B" Circuit Open

P0C5A16

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold

P0C5A17

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold

P0C6413

Generator Position Sensor Circuit "A" Circuit Open

P0C6416

Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold

P0C6417

Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold

P0C6913

Generator Position Sensor Circuit "B" Circuit Open

P0C6916

Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold

P0C6917

Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold

P0D2D16

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold

P0D2D17

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold

P0DFA62

Generator Phase U-V-W Current Sensor Signal Compare Failure

P0E0012

Generator Phase U Current Sensor Circuit Short to Battery

P0E0014

Generator Phase U Current Sensor Circuit Short to Ground or Open

P0E0028

Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0E0412

Generator Phase V Current Sensor Circuit Short to Battery

P0E0414

Generator Phase V Current Sensor Circuit Short to Ground or Open

P0E0428

Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0E0812

Generator Phase W Current Sensor Circuit Short to Battery

P0E0814

Generator Phase W Current Sensor Circuit Short to Ground or Open

Sensor and actuator circuit malfunction

Motor generator control system

P0E0828

Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0E3116

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold

P0E3117

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

P0E5111

DC/DC Converter Current Sensor Circuit Short to Ground

P0E5115

DC/DC Converter Current Sensor Circuit Short to Battery or Open

P0E5128

DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0E512A

DC/DC Converter Current Sensor Signal Stuck In Range

P1CAC49

Generator Position Sensor Internal Electronic Failure

P1CAD49

Drive Motor "A" Position Sensor Internal Electronic Failure

P1CAF38

Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect

P1CB038

Drive Motor "A" Position Sensor REF Signal Frequency Incorrect

P1CFF62

Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure

Hybrid control system

P0C7600

Hybrid/EV Battery System Discharge Time Too Long

P0D2D1C

Drive Motor "A" Inverter after Boosting Voltage Sensor Circuit Voltage Out of Range

P0E311C

Drive Motor "A" Inverter before Boosting Voltage Sensor Circuit Voltage Out of Range

System malfunction

Motor generator control system

P0A9000

Drive Motor "A" Performance

P0A9200

Hybrid Generator Performance

P0A949E

DC/DC Converter Stuck On

P0CA300

DC/DC Converter Step Up Voltage Performance

P0D3319

DC/DC Converter Circuit Current Above Threshold

P0E5717

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

P0E7100

Generator Execution Torque Performance

P1CA51D

Hybrid Generator Circuit Current Out of Range

P1CB59E

DC/DC Converter Voltage Sensor "A" (VL) Stuck On

P314F1F

DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent

P31531D

DC/DC Converter Current Sensor Circuit Current Out of Range

Hybrid control system

P0A9300

Inverter "A" Cooling System Performance

P0AA649

Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure

P0C7396

Motor Electronics Coolant Pump "A" Component Internal Failure

P314A31

Motor Electronics Coolant Pump "A" No Signal

Table 3

Relevant DTC

P0A3F1F

Drive Motor "A" Position Sensor Circuit Intermittent

P0A4B1F

Generator Position Sensor Circuit Intermittent

P0A601F

Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent

P0A631F

Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent

P0BE51F

Drive Motor "A" Phase U Current Sensor Circuit Intermittent

P0BE91F

Drive Motor "A" Phase V Current Sensor Circuit Intermittent

P0BED1F

Drive Motor "A" Phase W Current Sensor Circuit Intermittent

P0C501F

Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent

P0C5A1F

Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent

P0C641F

Generator Position Sensor Circuit "A" Circuit Intermittent

P0C691F

Generator Position Sensor Circuit "B" Circuit Intermittent

P0D2D1F

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent

P0E001F

Generator Phase U Current Sensor Circuit Intermittent

P0E041F

Generator Phase V Current Sensor Circuit Intermittent

P0E081F

Generator Phase W Current Sensor Circuit Intermittent

P0E311F

DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent

P0E511F

DC/DC Converter Current Sensor Circuit Intermittent

P1C601F

Generator Control Module Position Sensor REF Power Source Circuit Intermittent

P1C621F

Generator Control Module Offset Power Circuit Intermittent

P1C641F

Generator Control Module Circuit Intermittent

P1C651F

Generator Control Module Circuit Intermittent

P1C671F

Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent

P1C691F

Generator Phase U-V-W Current Sensor Circuit Intermittent

P31241F

Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent

HINT:

  • P0A7A9E or P1C5F19 may be output as a result of the malfunctions indicated by the DTCs above.
    1. The chart above is listed in inspection order of priority.
    2. Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
  • If DTC P0A7A9E is output, replace the inverter with converter assembly after completing repairs.

(e) Turn the power switch off.

A

GO TO STEP 5

B

GO TO DTC CHART (HYBRID CONTROL SYSTEM)

C

GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)

D

GO TO DTC CHART (HYBRID BATTERY SYSTEM)

3.

GO TO DTC CHART (P0A7A73)

Click here

HINT:

After repairs have been completed, perform the next step.

NEXT

4.

CHECK DTC OUTPUT

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.

(d) Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble Codes

Result

Proceed to

P0A7A9E or P1C5F19 only is output, or DTCs except the ones in the table below are also output.

A

DTCs of hybrid control system in the tables below are output.

B

DTCs of motor generator control system in the tables below are output.

C

Malfunction Content

System

Relevant DTC

Microcomputer malfunction

Motor generator control system

P0A1A47

Generator Control Module Watchdog / Safety μC Failure

P0A1A49

Generator Control Module Internal Electronic Failure

P0A1B1F

Generator Control Module Circuit Intermittent

P1C2A1C

Generator A/D Converter Circuit Circuit Voltage Out of Range

P1C2A49

Generator A/D Converter Circuit Internal Electronic Failure

P1C2B1C

Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range

P1C2B49

Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure

P313383

Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect

P313386

Communication Error from Generator to Drive Motor "A" Signal Invalid

P313387

Communication Error from Generator to Drive Motor "A" Missing Message

P313483

Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect

P313486

Communication Error from Drive Motor "A" to Generator Signal Invalid

P313487

Communication Error from Drive Motor "A" to Generator Missing Message

Hybrid control system

P0A1B49

Drive Motor "A" Control Module Internal Electronic Failure

Power source circuit malfunction

Motor generator control system

P06B01C

Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range

P06D61C

Generator Control Module Offset Power Circuit Voltage Out of Range

Communication malfunction

Motor generator control system

P312487

Lost Communication between Drive Motor "A" and HV ECU Missing Message

Hybrid control system

P312387

Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message

Sensor and actuator circuit malfunction

Motor generator control system

P0A3F16

Drive Motor "A" Position Sensor Circuit Voltage Below Threshold

P0A3F21

Drive Motor "A" Position Sensor Signal Amplitude < Minimum

P0A3F22

Drive Motor "A" Position Sensor Signal Amplitude > Maximum

P0A4B16

Generator Position Sensor Circuit Voltage Below Threshold

P0A4B21

Generator Position Sensor Signal Amplitude < Minimum

P0A4B22

Generator Position Sensor Signal Amplitude > Maximum

P0A6012

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery

P0A6014

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open

P0A601C

Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range

P0A6312

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery

P0A6314

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open

P0A631C

Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range

P0BE512

Drive Motor "A" Phase U Current Sensor Circuit Short to Battery

P0BE514

Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open

Sensor and actuator circuit malfunction

Motor generator control system

P0BE528

Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0BE912

Drive Motor "A" Phase V Current Sensor Circuit Short to Battery

P0BE914

Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open

P0BE928

Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0BED12

Drive Motor "A" Phase W Current Sensor Circuit Short to Battery

P0BED14

Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open

P0BED28

Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0BFD62

Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure

P0C5013

Drive Motor "A" Position Sensor Circuit "A" Circuit Open

P0C5016

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold

P0C5017

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold

P0C5A13

Drive Motor "A" Position Sensor Circuit "B" Circuit Open

P0C5A16

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold

P0C5A17

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold

P0C6413

Generator Position Sensor Circuit "A" Circuit Open

P0C6416

Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold

P0C6417

Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold

P0C6913

Generator Position Sensor Circuit "B" Circuit Open

P0C6916

Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold

P0C6917

Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold

P0D2D16

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold

P0D2D17

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold

P0DFA62

Generator Phase U-V-W Current Sensor Signal Compare Failure

P0E3116

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold

P0E3117

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

P0E5111

DC/DC Converter Current Sensor Circuit Short to Ground

P0E5115

DC/DC Converter Current Sensor Circuit Short to Battery or Open

P0E5128

DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

P0E512A

DC/DC Converter Current Sensor Signal Stuck In Range

P1CAC49

Generator Position Sensor Internal Electronic Failure

P1CAD49

Drive Motor "A" Position Sensor Internal Electronic Failure

P1CAF38

Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect

P1CB038

Drive Motor "A" Position Sensor REF Signal Frequency Incorrect

P1CFF62

Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure

Hybrid control system

P0C7600

Hybrid/EV Battery System Discharge Time Too Long

P0D2D1C

Drive Motor "A" Inverter after Boosting Voltage Sensor Circuit Voltage Out of Range

P0E311C

Drive Motor "A" Inverter before Boosting Voltage Sensor Circuit Voltage Out of Range

System malfunction

Motor generator control system

P0A9000

Drive Motor "A" Performance

P0A949E

DC/DC Converter Stuck On

P0CA300

DC/DC Converter Step Up Voltage Performance

P0D3319

DC/DC Converter Circuit Current Above Threshold

P0E5717

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

P0E7100

Generator Execution Torque Performance

P1CA51D

Hybrid Generator Circuit Current Out of Range

P1CB59E

DC/DC Converter Voltage Sensor "A" (VL) Stuck On

P314F1F

DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent

P31531D

DC/DC Converter Current Sensor Circuit Current Out of Range

Hybrid control system

P0A9300

Inverter "A" Cooling System Performance

P0AA649

Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure

P0C7396

Motor Electronics Coolant Pump "A" Component Internal Failure

P314A31

Motor Electronics Coolant Pump "A" No Signal

HINT:

  • P0A7A9E or P1C5F19 may be output as a result of the malfunctions indicated by the DTCs above.
    1. The chart above is listed in inspection order of priority.
    2. Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
  • If DTC P0A7A9E is output, replace the inverter with converter assembly after completing repairs.

(e) Turn the power switch off.

B

GO TO DTC CHART (HYBRID CONTROL SYSTEM)

C

GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)

A

5.

CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.

Powertrain > Motor Generator > Utility

Tester Display

Diagnosis Related Information

(d) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.

Powertrain > Motor Generator > Trouble Codes

(e) Read the diagnosis related information and freeze frame data of DTC P0A7A9E or P1C5F19.

Result

Proceed to

DTC P312487 is listed in Diagnosis Related Information.

A

DTC P312487 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON.

B

Other than above

C

(f) Turn the power switch off.

A

GO TO DTC CHART (P312487)

B

GO TO DTC CHART (P321E9F)

C

6.

CHECK COOLING SYSTEM

Click here

NEXT

7.

CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click here

Result

Proceed to

OK

A

NG (The connector is not connected securely.)

B

NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)

C

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

A

8.

CHECK GENERATOR RESOLVER CIRCUIT

Click here

NEXT

9.

CHECK MOTOR RESOLVER CIRCUIT

Click here

NEXT

10.

CHECK GENERATOR HIGH-VOLTAGE CIRCUIT

Click here

NEXT

11.

CHECK MOTOR HIGH-VOLTAGE CIRCUIT

Click here

NEXT

12.

CHECK INVERTER LOW-VOLTAGE CIRCUIT

Click here

HINT:

If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.

NEXT

REPLACE INVERTER WITH CONVERTER ASSEMBLY

READ NEXT:

 Drive Motor "A" Performance (P0A9000)

DTC SUMMARY MALFUNCTION DESCRIPTION This DTC indicates that magnetic force deterioration of the permanent magnet located in the rotor inside the motor (MG2) has been detected. The cause of this malfun

 Hybrid Generator Performance (P0A9200)

DTC SUMMARY MALFUNCTION DESCRIPTION This DTC indicates that magnetic force deterioration of the permanent magnet located in the rotor inside the generator (MG1) has been detected. The cause of this ma

 DC/DC Converter Stuck On (P0A949E,P0D3319)

DTC SUMMARY MALFUNCTION DESCRIPTION This DTC indicates that a large current flowed in the boost converter. The cause of this malfunction may be one of the following: Area Main Malfunction Descrip

SEE MORE:

 Parts Location

PARTS LOCATION ILLUSTRATION *1 CANISTER (CHARCOAL CANISTER ASSEMBLY) *2 FUEL TANK CAP ASSEMBLY *3 PCV VALVE (VENTILATION VALVE SUB-ASSEMBLY) *4 PURGE VALVE (PURGE VSV) *5 ECM *6 ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY - EFI-MAIN NO. 1 RELAY - EFI-MAIN NO. 1

 System Description

SYSTEM DESCRIPTION GENERAL (a) The parking support alert system has a static objects function, rear crossing vehicles function, and rear pedestrians. Parking Support Alert (static objects) function This system uses ultrasonic sensors to detect any obstacles at the corners and the rear of the v

© 2016-2024 Copyright www.lexguide.net