HYBRID BATTERY SYSTEM

DTC No.

Detection Item

MIL

Warning Indicate

Link

P056014

System Voltage (BATT) Circuit Short to Ground or Open

Comes on

Master Warning Light:

Comes on

P060629

Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid

Comes on

Master Warning Light:

Comes on

P060687

Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message

Comes on

Master Warning Light:

Comes on

P060A47

Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure

Comes on

Master Warning Light:

Comes on

P060A87

Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message

Comes on

Master Warning Light:

Comes on

P060B16

Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold

Comes on

Master Warning Light:

Comes on

P060B49

Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure

Comes on

Master Warning Light:

Comes on

P062F44

Hybrid/EV Battery Energy Control Module EEPROM Data Memory Failure

Comes on

Master Warning Light:

Does not come on

P062F46

Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure

Comes on

Master Warning Light:

Comes on

P0A1D94

Hybrid/EV Powertrain Control Module Unexpected Operation

Comes on

Master Warning Light:

Comes on

P0A8111

Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P0A8115

Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P0A8196

Hybrid/EV Battery Cooling Fan 1 Component Internal Failure

Comes on

Master Warning Light:

Comes on

P0A9563

High Voltage Fuse Accumulated Load History

Does not come on

Master Warning Light:

Does not come on

P0A9B11

Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P0A9B15

Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P0A9B1C

Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P0A9B2A

Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range

Comes on

Master Warning Light:

Comes on

P0AAC11

Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground

Does not come on

Master Warning Light:

Comes on

P0AAC15

Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open

Does not come on

Master Warning Light:

Comes on

P0ABF11

Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P0ABF15

Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P0ABF28

Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure

Comes on

Master Warning Light:

Comes on

P0ABF2A

Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range

Comes on

Master Warning Light:

Comes on

P0AC511

Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P0AC515

Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P0AC51C

Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P0AC52A

Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range

Comes on

Master Warning Light:

Comes on

P0ACA11

Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P0ACA15

Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P0ACA1C

Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P0ACA2A

Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range

Comes on

Master Warning Light:

Comes on

P0AE811

Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P0AE815

Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P0AE81C

Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P0AE82A

Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range

Comes on

Master Warning Light:

Comes on

P0B0E11

Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P0B0E15

Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P0B1362

Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure

Comes on

Master Warning Light:

Comes on

P0BC211

Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P0BC215

Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P0BC21C

Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P0BC22A

Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range

Comes on

Master Warning Light:

Comes on

P0C3000

Hybrid/EV Battery State of Charge High

Does not come on

Master Warning Light:

Comes on

P0C3311

Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P0C3315

Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P0C331C

Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P0C332A

Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range

Comes on

Master Warning Light:

Comes on

P0E2D00

Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance

Comes on

Master Warning Light:

Comes on

P1A001C

Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P1A6017

Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold

Comes on

Master Warning Light:

Comes on

P1A6116

Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold

Comes on

Master Warning Light:

Comes on

P1A8000

Hybrid/EV Battery Stack 1 Delta SOC High

Comes on

Master Warning Light:

Comes on

P1A8100

Hybrid/EV Battery Stack 1 Delta SOC High (Extreme)

Comes on

Master Warning Light:

Comes on

P1A8500

Hybrid/EV Battery Stack 2 Delta SOC High

Comes on

Master Warning Light:

Comes on

P1A8600

Hybrid/EV Battery Stack 2 Delta SOC High (Extreme)

Comes on

Master Warning Light:

Comes on

P1AC413

Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open

Comes on

Master Warning Light:

Comes on

P1AC49E

Hybrid/EV Battery Stack 1 Current Interrupt Device Stuck On

Comes on

Master Warning Light:

Comes on

P1AC513

Hybrid/EV Battery Stack 2 Current Interrupt Device Circuit Open

Comes on

Master Warning Light:

Comes on

P1AC59E

Hybrid/EV Battery Stack 2 Current Interrupt Device Stuck On

Comes on

Master Warning Light:

Comes on

P1AFC00

System Voltage (AM) Circuit Voltage Below Threshold

Does not come on

Master Warning Light:

Comes on

P1AFD00

Flying Capacitor Circuit Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P1AFD1C

Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P1AFF00

Hybrid/EV Battery ECU Multiple Reset

Does not come on

Master Warning Light:

Comes on

P1C8549

High Voltage Power Resource Internal Electronic Failure

Does not come on

Master Warning Light:

Comes on

P1C9F11

Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground

Comes on

Master Warning Light:

Comes on

P1C9F15

Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open

Comes on

Master Warning Light:

Comes on

P1C9F1C

Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P1CBB12

Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery

Comes on

Master Warning Light:

Comes on

P1CBB14

Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open

Comes on

Master Warning Light:

Comes on

P1CC81E

Hybrid/EV Battery Stack 1 Voltage Difference Out of Range

Comes on

Master Warning Light:

Comes on

P1CC91E

Hybrid/EV Battery Stack 2 Voltage Difference Out of Range

Comes on

Master Warning Light:

Comes on

P300000

Hybrid/EV Battery Discharge Control Malfunction

Does not come on

Master Warning Light:

Does not come on

P300016

Hybrid/EV Battery Control System Circuit Voltage Below Threshold

Does not come on

Master Warning Light:

Comes on

P30004B

Hybrid/EV Battery Control System Over Temperature

Does not come on

Master Warning Light:

Comes on

P301A1C

Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range

Comes on

Master Warning Light:

Comes on

P306562

Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure

Comes on

Master Warning Light:

Comes on

P306A62

Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure

Comes on

Master Warning Light:

Comes on

P31AA17

Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold

Comes on

Master Warning Light:

Comes on

P31AB16

Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold

Comes on

Master Warning Light:

Comes on

P31B300

Hybrid/EV Battery Voltage High

Comes on

Master Warning Light:

Comes on

P31B400

Extreme Hybrid/EV Battery Charging Current

Does not come on

Master Warning Light:

Comes on

P31B549

Hybrid/EV Battery Internal Electronic Failure

Does not come on

Master Warning Light:

Comes on

P33DA1E

Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range

Comes on

Master Warning Light:

Comes on

P33DB1E

Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range

Comes on

Master Warning Light:

Comes on

P33E01B

Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold

Comes on

Master Warning Light:

Comes on

P33E11B

Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold

Comes on

Master Warning Light:

Comes on

P33EC16

(Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold

Comes on

Master Warning Light:

Comes on

P33ED16

(Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold

Comes on

Master Warning Light:

Comes on

U010087

Lost Communication with ECM/PCM "A" Missing Message

Comes on

Master Warning Light:

Comes on

U029387

Lost Communication with Hybrid/EV Powertrain Control Module Missing Message

Comes on

Master Warning Light:

Comes on

U115087

Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message

Comes on

Master Warning Light:

Comes on

READ NEXT:

 System Voltage (BATT) Circuit Short to Ground or Open (P056014)

DESCRIPTION Auxiliary battery power is supplied to the AM terminal of the battery ECU assembly in order to store DTCs and freeze frame data. Even if the power switch is turned off, back-up power is su

 Vehicle Control History

VEHICLE CONTROL HISTORY VEHICLE CONTROL HISTORY (HYBRID BATTERY SYSTEM) (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following m

 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid (P060629)

DESCRIPTION The battery ECU assembly monitors its internal operation and will store these DTCs when it detects an internal malfunction. DTC No. Detection Item DTC Detection Condition Trouble