P033500

Crankshaft Position Sensor "A"

Normal driving

P033531

Crankshaft Position Sensor "A" No Signal

Normal driving

P034000

Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor

Normal driving

P034031

Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal

Normal driving

P062F44

Internal Control Module EEPROM Data Memory Failure

Normal driving

P062F46

Generator Control Module (EEPROM Learning Value) Calibration / Parameter Memory Failure

Reduced output power

P06B01C

Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range

Hybrid system stopped

P06D61C

Generator Control Module Offset Power Circuit Voltage Out of Range

Hybrid system stopped

P0A0011

Motor Electronics Coolant Temperature Sensor Circuit Short to Ground

Normal driving

P0A0015

Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open

Normal driving

P0A001C

Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range

Normal driving

P0A0812

DC/DC Converter Status Circuit Short to Battery

Normal driving

P0A0814

DC/DC Converter Status Circuit Short to Ground or Open

Normal driving

P0A1112

DC/DC Converter Enable Circuit Short to Battery

Normal driving

P0A1114

DC/DC Converter Enable Circuit Short to Ground or Open

Normal driving

P0A1A47

Generator Control Module Watchdog / Safety μC Failure

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P0A1A49

Generator Control Module Internal Electronic Failure

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P0A1B1F

Generator Control Module Circuit Intermittent

Hybrid system stopped

P0A3F16

Drive Motor "A" Position Sensor Circuit Voltage Below Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0A3F1F

Drive Motor "A" Position Sensor Circuit Intermittent

-

P0A3F21

Drive Motor "A" Position Sensor Signal Amplitude < Minimum

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0A3F22

Drive Motor "A" Position Sensor Signal Amplitude > Maximum

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0A4B16

Generator Position Sensor Circuit Voltage Below Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A4B1F

Generator Position Sensor Circuit Intermittent

-

P0A4B21

Generator Position Sensor Signal Amplitude < Minimum

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A4B22

Generator Position Sensor Signal Amplitude > Maximum

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A6012

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery

Normal driving

P0A6014

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open

Normal driving

P0A601C

Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range

Normal driving

P0A601F

Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent

-

P0A6312

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery

Normal driving

P0A6314

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open

Normal driving

P0A631C

Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range

Normal driving

P0A631F

Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent

-

P0A7872

Drive Motor "A" Inverter Actuator Stuck Open

  • Greatly reduced output power
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0A7873

Drive Motor "A" Inverter Actuator Stuck Closed

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0A789E

Drive Motor "A" Inverter Stuck On

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0A7A72

Generator Inverter Actuator Stuck Open

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A7A73

Generator Inverter Actuator Stuck Closed

  1. Normal driving
  2. Malfunction continues
    • Reduced output power
    • A driving range is limited
    • Engine always stopped
  3. Hybrid system stopped when malfunction continues

P0A7A9E

Generator Inverter Stuck On

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0A9000

Drive Motor "A" Performance

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0A9200

Hybrid Generator Performance

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A949E

DC/DC Converter Stuck On

  • Reduced output power
  • A driving range is limited
  • Engine not stopped

P0AED11

Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground

Normal driving

P0AED15

Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open

Normal driving

P0AED1C

Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range

Normal driving

P0BE512

Drive Motor "A" Phase U Current Sensor Circuit Short to Battery

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE514

Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE51F

Drive Motor "A" Phase U Current Sensor Circuit Intermittent

-

P0BE528

Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE912

Drive Motor "A" Phase V Current Sensor Circuit Short to Battery

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE914

Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE91F

Drive Motor "A" Phase V Current Sensor Circuit Intermittent

-

P0BE928

Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BED12

Drive Motor "A" Phase W Current Sensor Circuit Short to Battery

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BED14

Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BED1F

Drive Motor "A" Phase W Current Sensor Circuit Intermittent

-

P0BED28

Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BFD62

Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0BFF1D

Drive Motor "A" Circuit Current Out of Range

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0C1900

Drive Motor "A" Execution Torque Performance

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0C3811

DC/DC Converter Temperature Sensor "A" Circuit Short to Ground

Normal driving

P0C3815

DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open

Normal driving

P0C381C

DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range

Normal driving

P0C3D11

DC/DC Converter Temperature Sensor "B" Circuit Short to Ground

Normal driving

P0C3D15

DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open

Normal driving

P0C3D1C

DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range

Normal driving

P0C5013

Drive Motor "A" Position Sensor Circuit "A" Circuit Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5016

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5017

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0C501F

Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent

-

P0C5A13

Drive Motor "A" Position Sensor Circuit "B" Circuit Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5A16

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5A17

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5A1F

Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent

-

P0C6413

Generator Position Sensor Circuit "A" Circuit Open

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C6416

Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C6417

Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C641F

Generator Position Sensor Circuit "A" Circuit Intermittent

-

P0C6913

Generator Position Sensor Circuit "B" Circuit Open

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C6916

Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C6917

Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C691F

Generator Position Sensor Circuit "B" Circuit Intermittent

-

P0C7917

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold

  1. Normal driving
  2. Hybrid system stopped when malfunction continues

P0CA300

DC/DC Converter Step Up Voltage Performance

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P0D2D16

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold

Reduced output power

P0D2D17

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold

Reduced output power

P0D2D1F

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent

-

P0D3319

DC/DC Converter Circuit Current Above Threshold

  • Reduced output power
  • A driving range is limited
  • Engine not stopped

P0DFA62

Generator Phase U-V-W Current Sensor Signal Compare Failure

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0E0012

Generator Phase U Current Sensor Circuit Short to Battery

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E0014

Generator Phase U Current Sensor Circuit Short to Ground or Open

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E001F

Generator Phase U Current Sensor Circuit Intermittent

-

P0E0028

Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E0412

Generator Phase V Current Sensor Circuit Short to Battery

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E0414

Generator Phase V Current Sensor Circuit Short to Ground or Open

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E041F

Generator Phase V Current Sensor Circuit Intermittent

-

P0E0428

Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E0812

Generator Phase W Current Sensor Circuit Short to Battery

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E0814

Generator Phase W Current Sensor Circuit Short to Ground or Open

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E081F

Generator Phase W Current Sensor Circuit Intermittent

-

P0E0828

Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E3116

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold

Reduced output power

P0E3117

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

Reduced output power

P0E311F

DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent

-

P0E5111

DC/DC Converter Current Sensor Circuit Short to Ground

Reduced output power

P0E5115

DC/DC Converter Current Sensor Circuit Short to Battery or Open

Reduced output power

P0E511F

DC/DC Converter Current Sensor Circuit Intermittent

-

P0E5128

DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

Reduced output power

P0E512A

DC/DC Converter Current Sensor Signal Stuck In Range

Reduced output power

P0E5717

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

  • Reduced output power
  • A driving range is limited
  • Engine always stopped

P0E5811

DC/DC Converter Temperature Sensor 2 Circuit Short to Ground

Normal driving

P0E5815

DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open

Normal driving

P0E581C

DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range

Normal driving

P0E7100

Generator Execution Torque Performance

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P1C2A1C

Generator A/D Converter Circuit Circuit Voltage Out of Range

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P1C2A49

Generator A/D Converter Circuit Internal Electronic Failure

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P1C2B1C

Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range

Hybrid system stopped

P1C2B49

Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure

Hybrid system stopped

P1C2E46

Motor Generator ECU (EEPROM) Calibration / Parameter Memory Failure

-

P1C5D19

Drive Motor "A" Inverter Circuit Current Above Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P1C5F19

Generator Inverter Circuit Current Above Threshold

  1. Normal driving
  2. Malfunction continues
    • Reduced output power
    • A driving range is limited
    • Engine always stopped
  3. Hybrid system stopped when malfunction continues

P1C601F

Generator Control Module Position Sensor REF Power Source Circuit Intermittent

-

P1C621F

Generator Control Module Offset Power Circuit Intermittent

-

P1C641F

Generator Control Module Circuit Intermittent

-

P1C651F

Generator Control Module Circuit Intermittent

-

P1C671F

Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent

-

P1C691F

Generator Phase U-V-W Current Sensor Circuit Intermittent

-

P1CA51D

Hybrid Generator Circuit Current Out of Range

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P1CAC49

Generator Position Sensor Internal Electronic Failure

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P1CAD49

Drive Motor "A" Position Sensor Internal Electronic Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P1CAF38

Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P1CB038

Drive Motor "A" Position Sensor REF Signal Frequency Incorrect

  • Greatly reduced output power
  • Driving in reverse not possible
  • A driving range is limited
  • Engine used while driving and engine speed becomes high

P1CB59E

DC/DC Converter Voltage Sensor "A" (VL) Stuck On

  • Reduced output power
  • A driving range is limited
  • Engine not stopped

P1CB69E

Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On

Reduced output power

P1CCC96

DC/DC Converter Enable Component Internal Failure

Normal driving

P1CFF62

Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure

Reduced output power

P31241F

Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent

-

P312487

Lost Communication between Drive Motor "A" and HV ECU Missing Message

Hybrid system stopped

P313383

Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P313386

Communication Error from Generator to Drive Motor "A" Signal Invalid

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P313387

Communication Error from Generator to Drive Motor "A" Missing Message

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P313483

Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P313486

Communication Error from Drive Motor "A" to Generator Signal Invalid

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P313487

Communication Error from Drive Motor "A" to Generator Missing Message

  • Greatly reduced output power
  • A driving range is limited
  • Engine always stopped

P314F1F

DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent

Reduced output power

P31531D

DC/DC Converter Current Sensor Circuit Current Out of Range

Hybrid system stopped

U010087

Lost Communication With ECM/PCM "A" Missing Message

Normal driving

U029387

Lost Communication With Hybrid Powertrain Control Module Missing Message

Normal driving

U117087

Lost Communication With Brake System Control Module (ch2) Missing Message

Normal driving

(b) Relationship between the above and the multi-information display

Multi-information Display

Vehicle Behavior

Driving:
  • Hybrid system stopped Stop in a safe place
Stop:
  • Shift to [P] See owner's manual

Hybrid system stopped

Driving:
  • Hybrid system stopped Stop in a safe place
Stop:
  • Shift to [P] See owner's manual
  1. Normal driving
  2. When malfunction continues
    • Hybrid system stopped
Driving:
  • Stop in a safe place See owner's manual
  • Stop in a safe place within "○" miles
Stop:
  • Shift to [P] See owner's manual

A driving range is limited

Output power reduced Visit Your Dealer

Reduced output power

Output power greatly reduced Visit Your Dealer

Greatly reduced output power

Driving:
  • Output power reduced Avoid shifting to [N]
Stop:
  • Avoid shifting to [N] Visit Your Dealer
  • Reduced output power
  • Engine not stopped

"○": Varies depending on the remaining driving range.

READ NEXT:

 Data List / Active Test

DATA LIST / ACTIVE TEST DATA LIST NOTICE: Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obt

 Diagnostic Trouble Code Chart

DIAGNOSTIC TROUBLE CODE CHART Motor Generator Control System DTC No. Detection Item MIL Warning Indicate Link P033500 Crankshaft Position Sensor "A" Does not come on Master Warnin

 Crankshaft Position Sensor "A" (P033500,P033531)

DESCRIPTION If the crankshaft position signal pulse sent from the ECM via a direct line is abnormal, the motor generator control ECU (MG ECU) (built into the inverter with converter assembly) stores D

SEE MORE:

 Parts Location

PARTS LOCATION ILLUSTRATION *1 FAN WITH MOTOR ASSEMBLY - COOLING FAN MOTOR - COOLING FAN ECU *2 ECM *3 NO. 1 ENGINE ROOM RELAY BLOCK AND NO. 1 JUNCTION BLOCK ASSEMBLY - EFI-MAIN NO. 1 RELAY - -

 Hybrid/EV Battery Sensor Module Signal Compare Failure (P0AFC62,...,P308A13)

DESCRIPTION Refer to the description for DTC P1AC000. Click here DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate P0AFC62 Hybrid/EV Battery Sensor Module Signal Compare Failure The difference between the voltage output by detection circuit C and

© 2016-2024 Copyright www.lexguide.net