Lexus ES: Motor Generator Control Computer
READ NEXT:
PRECAUTION 1.PRECAUTION WHEN REMOVING/INSTALLING INVERTER WITH CONVERTER ASSEMBLY CAUTION:
Do not push down or apply excessive force to the inverter with converter assembly.
Be careful not to inj
COMPONENTS ILLUSTRATION *1 WIRE HARNESS CLAMP BRACKET *2 INVERTER WITH CONVERTER ASSEMBLY *3 INVERTER PROTECTOR - - N*m (kgf*cm, ft.*lbf): Specified torque - - ILLUST
REMOVAL CAUTION / NOTICE / HINT The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during mot
SEE MORE:
INSPECTION PROCEDURE 1. INSPECT HYBRID BATTERY TERMINAL BLOCK (a) Measure the resistance according to the value(s) in the table below. Standard Resistance: Tester Connection Condition Specified Condition Hybrid Battery Terminal Block Always Below 1 Ω If the result is not as sp
DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs indicate that the boost converter temperature sensor (upper) value is abnormal. The cause of this malfunction may be one of the following: Internal inverter malfunction
Inverter with converter assembly internal circuit malfunction
Hybrid cooling