DESCRIPTION
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors its internal operation and detects malfunctions.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
---|---|---|---|---|---|
P1C651F | Generator Control Module Circuit Intermittent | Excitation signal (REF signal) for resolver angle detection cycle malfunction detected when DTC P0C7917, P0D3319, P0E5717, P1C5D19 or P1C5F19 is stored. (1 trip detection logic) |
| Does not come on | Master Warning Light: Does not come on |
P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | Motor resolver angle malfunction: The difference between the resolver angle for control and estimated resolver angle exceeds the allowable limit. (1 trip detection logic) |
| Comes on | Master Warning Light: Comes on |
P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | Resolver REF signal cycle malfunction: Excitation signal (REF signal) for resolver angle detection cycle malfunction (1 trip detection logic) |
| Comes on | Master Warning Light: Comes on |
HINT:
Although the DTC titles generator control module, these DTCs relate to the motor control module.
Related Data List DTC No. | Data List |
---|---|
P1CAD49 | Motor Revolution |
P1CB038 |
MONITOR DESCRIPTION
The motor generator control ECU performs diagnostic tests to verify proper operation of internal ECU systems. In one of those tests, the motor generator control ECU checks for an R/D (Resolver/ Digital converter) malfunction involving the motor resolver. If the motor generator control ECU detects an R/D converter error, it will conclude that there is an internal malfunction involving the motor resolver. The motor generator control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
Related DTCs | P1CAD (INF P1CAD49): Drive Motor "A" Control Module R/D Processing (Drive Motor "A" Position) Performance P1CB0 (INF P1CB038): Drive Motor "A" Position Sensor Reference Signal Performance |
Required sensors/components | Motor resolver |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | Immediately |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored | TMC's intellectual property |
Other conditions belong to TMC's intellectual property | - |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P1CAD (INF P1CAD49) is not detected DTC P1CB0 (INF P1CB038) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
Click here
Click here
*: Lightly wiggle the connectors and wire harnesses up and down and right and left.
HINT:
[*1] to [*6]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
HINT:
WIRING DIAGRAM
Refer to the wiring diagram for DTC P1CAC49.
Click here
CAUTION / NOTICE / HINT
CAUTION:
Click here
HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a | Without waiting for 10 minutes |
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
HINT:
PROCEDURE
1. | CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL) |
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Motor Generator > Trouble Codes Result | Proceed to |
---|---|
P1CAD49, P1CB038 or P1C651F only is output, or DTCs except the ones in the table below are also output. | A |
Any of the following DTCs are also output. | B |
Relevant DTC | |
---|---|
P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold |
P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
(e) Turn the power switch off.
B | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
2. | CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
Result | Proceed to |
---|---|
OK | A |
NG (The connector is not connected securely.) | B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
B | CONNECT SECURELY |
C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
3. | CHECK GENERATOR RESOLVER CIRCUIT |
Click here
|
4. | CHECK MOTOR RESOLVER CIRCUIT |
Click here
HINT:
If the "Motor Resolver Circuit" inspection results are normal, perform the next step.
NEXT | REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS |