Lexus ES: Blind Spot Monitor Master Module Beam Axis Inspection Incomplete (C1ABB)
DESCRIPTION
This DTC is stored when a beam axis inspection has not been performed for the blind spot monitor sensor RH.
HINT:
This DTC is always stored after replacing a blind spot monitor sensor. The purpose of this DTC is to ensure that a beam axis inspection is performed. Completing the beam axis inspection after replacing a blind spot monitor sensor prevents this DTC from being output.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
C1ABB | Blind Spot Monitor Master Module Beam Axis Inspection Incomplete | A beam axis inspection has not been performed | Blind spot monitor sensor RH |
PROCEDURE
1. | PROCEED TO TEST MODE (BLIND SPOT MONITOR BEAM AXIS INSPECTION) |
(a) Change the blind spot monitor sensor RH to Test Mode using the Techstream.
HINT:
Refer to Blind Spot Monitor Beam Axis Inspection.
Click here
NEXT | | END |
READ NEXT:
DESCRIPTION This DTC is stored when a beam axis inspection has not been performed for the blind spot monitor sensor LH. HINT: This DTC is always stored after replacing a blind spot monitor sensor. The
DESCRIPTION
DTC C1ABE is stored when the blind spot monitor sensor LH detects a short to ground or open in the RCTA buzzer (blind spot monitor buzzer) circuit.
DTC No. Detection Item DTC
DESCRIPTION This DTC is stored when the angle of the blind spot monitor sensor RH deviates more than the allowable range from the horizontal axis. HINT:
If a drum tester such as a speedometer teste
SEE MORE:
DESCRIPTION The main body ECU (multiplex network body ECU) controls the operation of the TAIL relay. WIRING DIAGRAM CAUTION / NOTICE / HINT NOTICE:
Inspect the fuses for circuits related to this system before performing the following procedure.
Before replacing the main body ECU (multiplex net
DTC SUMMARY MALFUNCTION DESCRIPTION When the power switch is turned from on (READY) to off, the hybrid vehicle control ECU detect that the high-voltage capacitor inside the inverter with converter assembly is not discharged. The cause of this malfunction may be one of the following: Inverter voltag
© 2016-2025 Copyright www.lexguide.net