DESCRIPTION
When replacing the No. 1 HV supply stack sub-assembly or No. 2 HV supply stack sub-assembly, it is necessary to check, adjust and equalize the SOC of the HV battery. Otherwise, the engine may run longer than normal, resulting in a decrease in fuel efficiency.
PROCEDURE
1. | READ VALUE USING TECHSTREAM (Hybrid Battery SOC) |
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Powertrain / HV Battery / Data List / Hybrid Battery SOC.
(e) Read the Data List.
Powertrain > HV Battery > Data List Tester Display |
---|
Hybrid Battery SOC |
Result | Proceed to |
---|---|
"Hybrid Battery SOC" is 55 to 65% | A |
Other than above | B |
(f) Turn the power switch off.
A | GO TO STEP 3 |
|
2. | ADJUST HV BATTERY SOC |
HINT:
If the following procedure (charging or discharging of the HV battery) cannot be performed due to the condition of the vehicle, proceed to the next step.
(a) Apply the parking brake and chock all 4 wheels.
(b) Connect the Techstream to the DLC3.
(c) Turn the power switch on (IG).
(d) Turn the Techstream on.
(e) Enter the following menus: Powertrain / HV Battery / Data List / Hybrid Battery SOC.
(f) Depress the accelerator pedal and brake pedal simultaneously or leave the vehicle with neutral (N) selected until the value of Data List item "Hybrid Battery SOC" is between 55% and 65%.
Powertrain > HV Battery > Data List Tester Display |
---|
Hybrid Battery SOC |
HINT:
(g) Turn the power switch off.
|
3. | REPLACE HV BATTERY (NO. 1 HV SUPPLY STACK SUB-ASSEMBLY or NO. 2 HV SUPPLY STACK SUB-ASSEMBLY) |
Click here
|
4. | ROAD TEST |
(a) Turn the power switch on (READY).
(b) Drive the vehicle on urban roads for approximately 10 minutes.
HINT:
Perform this procedure in order to ensure the accuracy of the inspection in the next step.
(c) Turn the power switch off.
|
5. | READ VALUE USING TECHSTREAM (Delta SOC) |
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Powertrain / HV Battery / Data List / Delta SOC.
(e) Check and Record the Data List.
Powertrain > HV Battery > Data List Tester Display |
---|
Delta SOC |
Result | Proceed to |
---|---|
"Delta SOC" is 0 to 5% | A |
Other than above | B |
(f) Turn the power switch off.
A | END |
|
6. | TIME TO EQUALIZE SOC |
(a) According to the value of Data List item "Delta SOC" recorded in the previous step, equalize the SOC.
"Delta SOC" | Time to Equalize SOC (Total time necessary to leave power switch off) |
---|---|
6 to 10% | 29 hours |
11 to 15% | 49 hours |
16 to 20% | 66 hours |
21 to 25% | 85 hours |
26 to 30% | 103 hours |
HINT:
NEXT | END |