(a) Vehicle behavior categorized by DTC

If a DTC is output, the vehicle behaves as follows.

DTC No.

Detection Item

Vehicle Behavior when DTC is Output

P056014

System Voltage (BATT) Circuit Short to Ground or Open

-

P060647

Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure

Hybrid system stopped

P060687

Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message

Hybrid system stopped

P060694

Hybrid/EV Powertrain Control Module Processor Unexpected Operation

  1. Normal driving
  2. When malfunction continues
    • Hybrid system stopped

P060A29

Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid

Hybrid system stopped

P060A44

Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure

Hybrid system stopped

P060A45

Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure

Hybrid system stopped

P060A47

Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure

Hybrid system stopped

P060A49

Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure

Hybrid system stopped

P060A87

Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message

Hybrid system stopped

P060A94

Hybrid/EV Powertrain Control Module Monitoring Processor Performance Unexpected Operation

  1. Normal driving
  2. When malfunction continues
    • Hybrid system stopped

P060B1C

Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range

Hybrid system stopped

P060B49

Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure

Hybrid system stopped

P060B71

Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck

Hybrid system stopped

P062F44

Hybrid/EV Powertrain Control Module EEPROM Data Memory Failure

Normal driving

P06881F

ECM/PCM Power Relay Sense Circuit Intermittent

Hybrid system stopped

P070562

Transmission Range Sensor "A" Circuit (PRNDL Input) Signal Compare Failure

Normal driving

(N position control used for the malfunctioning shift position)

P0A0A13

High Voltage System Interlock Circuit Open

Normal driving

P0A0A92

High Voltage System Interlock Performance or Incorrect Operation

Hybrid system stopped

P0A1B49

Drive Motor "A" Control Module Internal Electronic Failure

Hybrid system stopped

P0A1B94

Drive Motor "A" Control Module Unexpected Operation

  1. Normal driving
  2. When malfunction continues
    • Hybrid system stopped

P0A1F94

Hybrid/EV Battery Energy Control Module Unexpected Operation

  • Reduced output power
  • Engine does not stop

P0A2A11

Drive Motor "A" Temperature Sensor Circuit Short to Ground

Normal driving

P0A2A15

Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open

Normal driving

P0A2A1C

Drive Motor "A" Temperature Sensor Voltage Out of Range

Normal driving

P0A2A1F

Drive Motor "A" Temperature Sensor Circuit Intermittent

Normal driving

P0A3611

Generator Temperature Sensor Circuit Short to Ground

Normal driving

P0A3615

Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open

Normal driving

P0A361C

Generator Temperature Sensor Voltage Out of Range

Normal driving

P0A361F

Generator Temperature Sensor Circuit Intermittent

Normal driving

P0A9300

Inverter "A" Cooling System Performance

  • Greatly reduced output power
  • A Driving range is limited

P0AA000

Hybrid/EV Battery Positive Contactor Circuit Stuck Closed

Hybrid system stopped

P0AA073

Hybrid/EV Battery Positive and Negative Contactor Actuator Stuck Closed

Hybrid system stopped

P0AA373

Hybrid/EV Battery Negative Contactor Actuator Stuck Closed

Hybrid system stopped

P0AA649

Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure

Normal driving

P0AA749

Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure

Normal driving

P0ABF00

Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance

  • Reduced output power
  • Engine does not stop

P0AD911

Hybrid/EV Battery Positive Contactor Circuit Short to Ground

Hybrid system stopped

P0AD915

Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open

Hybrid system stopped

P0ADD11

Hybrid/EV Battery Negative Contactor Circuit Short to Ground

Hybrid system stopped

P0ADD15

Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open

Hybrid system stopped

P0AE173

Hybrid/EV Battery Precharge Contactor Actuator Stuck Closed

Hybrid system stopped

P0AE411

Hybrid/EV Battery Precharge Contactor Circuit Short to Ground

Normal driving

P0AE415

Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open

Normal driving

P0B231C

Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range

  • Reduced output power
  • Engine does not stop

P0C7396

Motor Electronics Coolant Pump "A" Component Internal Failure

  • Greatly reduced output power
  • A Driving range is limited

P0C7600

Hybrid/EV Battery System Discharge Time Too Long

Hybrid system stopped

P0D2D1C

Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range

Reduced output power

P0E311C

Boosting Converter Voltage Sensor "A" Voltage Out of Range

Normal driving

P160600

Collision detected or Collision Sensor Connection (Open)

Hybrid system stopped

P160604

Collision detected or Collision Sensor Connection (Open) System Internal Failure

Hybrid system stopped

P1AC413

Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open

  • Reduced output power
  • Engine not stopped

P1C2D62

Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure

Reduced output power

P1C6A9F

Motor Shutdown Stuck Off

Hybrid system stopped

P1C6C9F

Generator Shutdown Stuck Off

Hybrid system stopped

P1C7779

Engine Failed to Start Mechanical Linkage Failure

  • Reduced output power
  • A Driving range is limited
  • Engine always stopped

P1C7C49

Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure

Normal driving

P1C7D49

Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure

Normal driving

P1C7E49

Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure

Normal driving

P1C7F49

Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure

Normal driving

P1C8149

High Voltage Power Resource Circuit Consumption Circuit Short

Hybrid system stopped

P1C8249

High Voltage Power Resource Circuit Over Loading

Hybrid system stopped

P1C8349

High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction

Hybrid system stopped

P1C8449

High Voltage Power Resource Circuit Short during Ready ON

Hybrid system stopped

P1C8679

Transmission (Input) Mechanical Linkage Failure

  • Reduced output power
  • A Driving range is limited
  • Engine always stopped

P1C8779

Generator Mechanical Linkage Failure

  • Reduced output power
  • A Driving range is limited
  • Engine always stopped

P1C8879

Planetary Gear Mechanical Linkage Failure

  • Reduced output power
  • A Driving range is limited
  • Engine always stopped

P1C9E9F

Hybrid/EV System Reset Stuck Off

Hybrid system stopped

P1CE213

PCU Interlock Circuit Open

Normal driving

P1CE292

PCU Interlock Performance or Incorrect Operation

Hybrid system stopped

P1CE31C

Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range

-

P1CE349

Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure

-

P1CE371

Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck

-

P1CFA12

IGB Signal Circuit Short to Auxiliary Battery

-

P212012

Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Auxiliary Battery

Reduced output power

P212014

Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Ground or Open

Reduced output power

P21201C

Throttle/Pedal Position Sensor/Switch "D" Voltage Out of Range

Reduced output power

P21201F

Throttle/Pedal Position Sensor/Switch "D" Circuit Intermittent

Reduced output power

P212512

Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Auxiliary Battery

Reduced output power

P212514

Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Ground or Open

Reduced output power

P21251C

Throttle/Pedal Position Sensor/Switch "E" Voltage Out of Range

Reduced output power

P21251F

Throttle/Pedal Position Sensor/Switch "E" Circuit Intermittent

Reduced output power

P213800

Throttle/Pedal Position Sensor/Switch "D"/"E" Voltage Correlation

Reduced output power

P21382B

Throttle/Pedal Position Sensor/Switch "D"/"E" Signal Cross Coupled

Greatly reduced output power

P253012

IG2 Signal Circuit Short to Auxiliary Battery

Hybrid system stopped

P274A11

Transmission Fluid Temperature Sensor "C" Circuit Short to Ground

Normal driving

P274A15

Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open

Normal driving

P274A1C

Transmission Fluid Temperature Sensor "C" Voltage Out of Range

Normal driving

P274A1F

Transmission Fluid Temperature Sensor "C" Circuit Intermittent

Normal driving

P300449

High Voltage Power Resource Circuit Short during Pre-Charge

Hybrid system stopped

P310711

Lost Communication with Airbag System Control Module Circuit Short to Ground

Normal driving

P310715

Lost Communication with Airbag System Control Module Circuit Short to Auxiliary Battery or Open

Normal driving

P310764

Lost Communication with Airbag System Control Module Signal Plausibility Failure

Normal driving

P312387

Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message

Hybrid system stopped

P314779

Transmission (Shaft) Mechanical Linkage Failure

Hybrid system stopped

P314A31

Motor Electronics Coolant Pump "A" No Signal

Normal driving

P31B300

Hybrid/EV Battery Voltage High

  • Reduced output power
  • Engine does not stop

P321E9F

Motor/Generator Shutdown Signal Stuck Off

Normal driving

P33B99F

Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off

Normal driving

P33BF9F

Motor/Generator Shutdown Signal (MG Side) Stuck Off

Normal driving

U010087

Lost Communication with ECM/PCM "A" Missing Message

  • Reduced output power
  • A Driving range is limited
  • Engine always stopped

U010487

Lost Communication with Cruise Control Module Missing Message

Normal driving

U011087

Lost Communication with Drive Motor Control Module "A" Missing Message

Normal driving

U011187

Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message

  • Reduced output power
  • Engine does not stop

U012287

Lost Communication with Vehicle Dynamics Control Module Missing Message

Normal driving

U012987

Lost Communication with Brake System Control Module Missing Message

Normal driving

U014087

Lost Communication with Body Control Module Missing Message

Normal driving

U015187

Lost Communication with Restraints Control Module Missing Message

Normal driving

U016487

Lost Communication with HVAC Control Module Missing Message

-

U029387

Lost Communication with Hybrid/EV Powertrain Control Module Missing Message

Normal driving

U042481

HVAC Control Module to Hybrid Powertrain Control Module Invalid Serial Data Received

-

U110787

Lost Communication with Power Management Module Missing Message

Hybrid system stopped

U117087

Lost Communication with Brake System Control Module (Secondary CAN Line) Missing Message

Normal driving

U117587

Lost Communication with Hybrid/EV Battery Energy Control Module "A" (Powertrain Bus) Missing Message

  • Reduced output power
  • Engine does not stop

(b) Relationship between the above and the multi-information display

Multi-information Display

Vehicle Behavior

Visit Your Dealer

Normal driving

Driving:
  • Hybrid System Stopped Stop in a Safe Place
Stop:
  • Shift to [P] See Owner's Manual

Hybrid system stopped

Driving:
  • Hybrid System Stopped Stop in a Safe Place
Stop:
  • Shift to [P] See Owner's Manual
  1. Normal driving
  2. When malfunction continues
    • Hybrid system stopped
  • Normal driving
Driving:
  • Stop in a safe place See owner's manual
  • Stop in a safe place within "○" km
Stop:
  • Shift to [P] See Owner's Manual

A Driving range is limited

Output Power Reduced Visit Your Dealer

Reduced output power

Output Power Greatly Reduced Visit Your Dealer

Greatly reduced output power

Driving:
  • Output Power Reduced Avoid Shifting to [N]
Stop:
  • Avoid Shifting to [N] Visit Your Dealer
  • Reduced output power
  • Engine does not stop

"○": Varies depending on the remaining driving range.

READ NEXT:

 Data List / Active Test

DATA LIST / ACTIVE TEST DATA LIST NOTICE: Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obt

 Vehicle Control History

VEHICLE CONTROL HISTORY CHECK VEHICLE CONTROL HISTORY (HYBRID CONTROL SYSTEM) (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the follo

 System Voltage (BATT) Circuit Short to Ground or Open (P056014)

DESCRIPTION Auxiliary battery power is supplied to the BATT terminal of the hybrid vehicle control ECU in order to store DTCs and freeze frame data. Even if the power switch is turned off, back-up pow

SEE MORE:

 Washer Fluid Level Warning Switch Circuit

DESCRIPTION When the washer fluid level is lower than a certain level, a warning message is displayed on the combination meter assembly. WIRING DIAGRAM PROCEDURE 1. READ VALUE USING TECHSTREAM (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstrea

 ENG / EHV Device (C1A40)

DESCRIPTION When a SFI system malfunction signal sent by the hybrid vehicle control ECU is detected by the clearance warning ECU assembly, DTC C1A40 is stored. DTC No. Detection Item DTC Detection Condition Trouble Area C1A40 ENG / EHV Device When the power switch on (IG), a SFI sys

© 2016-2024 Copyright www.lexguide.net