Lexus ES: On-vehicle Inspection

ON-VEHICLE INSPECTION

PROCEDURE

1. INSPECT CAMSHAFT TIMING OIL CONTROL SOLENOID ASSEMBLY

(a) Connect the Techstream to the DLC3.

(b) Start the engine.

(c) Turn the Techstream on.

(d) Inspect the camshaft timing oil control solenoid assembly (for intake side).

(1) Enter the following menus: Powertrain / Engine / Active Test / Control the Intake VVT OCV Duty Ratio Bank 1 or Control the Intake VVT OCV Duty Ratio Bank 2 / Data List / Intake VVT Change Angle Bank 1 or Intake VVT Change Angle Bank 2.

Powertrain > Engine > Active Test

Active Test Display

Control the Intake VVT OCV Duty Ratio Bank 1

Data List Display

Intake VVT Change Angle Bank 1

Powertrain > Engine > Active Test

Active Test Display

Control the Intake VVT OCV Duty Ratio Bank 2

Data List Display

Intake VVT Change Angle Bank 2

(2) Read the Data List while performing the Active Test with the engine idling.

OK:

Techstream Operation

Data List (Intake VVT Change Angle Bank 1 or Intake VVT Change Angle Bank 2)

-100% to 100%

Varies by 70 DegFR or more

If the result is not as specified, check the camshaft timing oil control solenoid assembly, wire harness and ECM.

(e) Inspect the camshaft timing oil control solenoid assembly (for exhaust side).

(1) Enter the following menus: Powertrain / Engine / Active Test / Control the Exhaust VVT OCV Duty Ratio Bank 1 or Control the Exhaust VVT OCV Duty Ratio Bank 2.

Powertrain > Engine > Active Test

Tester Display

Control the Exhaust VVT OCV Duty Ratio Bank 1

Powertrain > Engine > Active Test

Tester Display

Control the Exhaust VVT OCV Duty Ratio Bank 2

(2) Check the engine speed while operating the camshaft timing oil control solenoid assembly (for exhaust camshaft) using the Techstream.

OK:

Techstream Operation

Engine Condition

0%

Normal engine speed

100%

Engine idles roughly or stalls

HINT:

Refer to "Data List / Active Test" [Exhaust VVT OCV Control Duty Ratio Bank 1, Exhaust VVT Change Angle Bank 1, Exhaust VVT OCV Control Duty Ratio Bank 2 and Exhaust VVT Change Angle Bank 2].

Click here

If the result is not as specified, check the camshaft timing oil control solenoid assembly, wire harness and ECM.

READ NEXT:

 Removal

REMOVAL CAUTION / NOTICE / HINT The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during cams

 Inspection

INSPECTION PROCEDURE 1. INSPECT CAMSHAFT TIMING OIL CONTROL SOLENOID ASSEMBLY HINT: Use the same procedure for the intake side and exhaust side. (a) Check the resistance. (1) Measure the resistance

 Installation

INSTALLATION PROCEDURE 1. INSTALL CAMSHAFT TIMING OIL CONTROL SOLENOID ASSEMBLY (for Intake Side of Bank 2) (a) Apply engine oil to a new O-ring and install it to the camshaft timing oil control so

SEE MORE:

 Fuel Rail Pressure Sensor (Low) Signal Stuck in Range (P107A2A,P107A64)

DESCRIPTION Refer to DTC P107A11. Click here DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note P107A2A Fuel Rail Pressure Sensor (Low) Signal Stuck in Range When target low pressure side fuel pressure changes, the change in fuel pressure sensor valu

 Components

COMPONENTS ILLUSTRATION *1 FUEL PRESSURE SENSOR *2 NO. 1 FUEL PRESSURE SENSOR HOLDER Tightening torque for "Major areas involving basic vehicle performance such as moving/turning/stopping": N*m (kgf*cm, ft.*lbf) ● Non-reusable part

© 2016-2025 Copyright www.lexguide.net