INITIALIZATION
DESCRIPTION
(a) Always perform linear solenoid valve offset learning, ABS holding solenoid valve learning, brake pedal stroke sensor assembly zero point calibration and system information memorization after the skid control ECU (brake booster with master cylinder assembly), brake pedal stroke sensor assembly, brake pedal or brake actuator assembly is replaced.
Follow the procedure to perform initialization.
NOTICE:
After performing linear solenoid valve offset learning, ABS holding solenoid valve learning, brake pedal stroke sensor assembly zero point calibration and system information memorization, learning cannot be performed again until the data stored during learning has been cleared. When replacing a part, always perform learning after clearing data stored during previous learning.
Part to be Replaced | Necessary Operation |
---|---|
|
|
|
|
PERFORM LINEAR SOLENOID VALVE OFFSET LEARNING, ABS HOLDING SOLENOID VALVE LEARNING, BRAKE PEDAL STROKE SENSOR ASSEMBLY ZERO POINT CALIBRATION AND SYSTEM INFORMATION MEMORIZATION
NOTICE:
Click here
HINT:
(a) To ensure that linear solenoid valve offset learning, ABS holding solenoid valve learning, brake pedal stroke sensor assembly zero point calibration and system information memorization completes successfully, ensure that the following conditions are met before proceeding:
(1) The auxiliary battery voltage is 11 to 15.5 V when the power switch is on (READY).
(2) The brake actuator (brake booster with master cylinder assembly) is not hot.
(3) The brake actuator assembly is not hot.
HINT:
If the brake actuator (brake booster with master cylinder assembly) or brake actuator assembly is hot, wait until it cools down before performing linear solenoid valve offset learning, ABS holding solenoid valve learning, brake pedal stroke sensor assembly zero point calibration and system information memorization.
(b) Clear the data stored during previous linear solenoid valve offset learning, ABS holding solenoid valve learning, brake pedal stroke sensor assembly zero point calibration and system information memorization.
(1) Turn the power switch off.
(2) Check that the steering wheel is centered.
(3) Check that the shift lever is in P.
(4) Connect the Techstream to the DLC3.
(5) Turn the power switch on (IG).
(6) Turn the Techstream on.
(7) Using the Techstream, clear the data stored during previous linear solenoid valve offset learning, ABS holding solenoid valve learning, brake pedal stroke sensor assembly zero point calibration and system information memorization. Enter the following menus: Chassis / ABS/VSC/TRAC / Utility / Reset Memory.
Chassis > ABS/VSC/TRAC > Utility Tester Display |
---|
Reset Memory |
NOTICE:
Always perform yaw rate and acceleration sensor zero point calibration after performing "Reset Memory" as the data stored during yaw rate and acceleration sensor zero point calibration is cleared when "Reset Memory" is performed.
(8) Turn the power switch off.
NOTICE:
If the power switch is turned on (IG) for more than 15 seconds with the shift lever in P after the zero point of the yaw rate and acceleration sensor has been cleared, only the zero point of the yaw rate sensor will be stored. If the vehicle is driven under these conditions, the skid control ECU (brake booster with master cylinder assembly) will store the zero point calibration for the acceleration sensor as not being completed. The skid control ECU (brake booster with master cylinder assembly) will then also indicate this as a malfunction of the VSC system using the indicator light.
(c) Perform linear solenoid valve offset learning, ABS holding solenoid valve learning, brake pedal stroke sensor assembly zero point calibration and system information memorization.
(1) Turn the power switch off.
(2) Check that the steering wheel is centered.
(3) Check that the shift lever is in P.
(4) Check that the parking brake is released.
NOTICE:
(5) Connect the Techstream to the DLC3.
(6) Turn the power switch on (IG) with the brake pedal released.
(7) Turn the Techstream on.
(8) Switch the skid control ECU (brake booster with master cylinder assembly) to Test Mode using the Techstream. Enter the following menus: Chassis / ABS/VSC/TRAC / Utility / ECB* Utility / Linear Valve Offset.
*: Electronically Controlled Brake System
Chassis > ABS/VSC/TRAC > Utility Tester Display |
---|
ECB Utility |
(9) Leave the vehicle stationary without depressing the brake pedal for approximately 4 minutes.
(10) Check that the blink interval of the brake warning light / yellow (minor malfunction) changes from 1 second to 0.25 seconds within the first half (approximately 2 minutes) to indicate that linear solenoid valve offset learning is complete, and that the blink interval of the ABS warning light changes from 1 second to 0.25 seconds within the second half (approximately 2 minutes) to indicate that ABS holding solenoid valve learning is complete.
NOTICE:
HINT:
If the auxiliary battery voltage drops below 10 V, learning may be canceled.
The time required for learning changes depending on the auxiliary battery voltage.
Linear Solenoid Valve Offset Learning Condition | ABS Holding Solenoid Valve Learning Condition | Brake warning light / yellow (minor malfunction) | ABS warning light |
---|---|---|---|
Learning not complete | Learning not performed | Blinks at 1 second intervals | Blinks at 0.25 second intervals |
Learning complete | Learning not complete | Blinks at 0.25 second intervals | Blinks at 1 second intervals |
Learning complete | Blinks at 0.25 second intervals | Blinks at 0.25 second intervals |
(11) Check that "complete" is displayed for Test Mode (Signal Check) items "Learning of Stroke Sensor Zero Point" and "Memory of System Information".
(12) Perform zero point calibration of the yaw rate and acceleration sensor.
Click here
(13) Return to normal mode from Test Mode following the Techstream directions.
HINT:
Refer to the Techstream operator's manual for further details.
(14) Turn the power switch off and disconnect the Techstream.