Lexus ES: Hybrid/EV Battery Energy Control Module Unexpected Operation (P0A1F94)

Lexus ES (XZ10) Service Manual / Engine & Hybrid System / Hybrid / Battery Control / Hybrid Control System (for Lithium-ion Battery) / Hybrid/EV Battery Energy Control Module Unexpected Operation (P0A1F94)

DTC SUMMARY

MALFUNCTION DESCRIPTION

The hybrid vehicle control ECU (main CPU) monitors the battery ECU assembly.

The cause of this malfunction may be the following:

Battery ECU assembly internal malfunction
  • Battery ECU assembly malfunction

DESCRIPTION

The hybrid vehicle control ECU (main CPU) monitors the battery ECU assembly and stores this DTC when it detects a malfunction.

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

P0A1F94

Hybrid/EV Battery Energy Control Module Unexpected Operation

The battery ECU assembly value received by the hybrid vehicle control ECU (main CPU) exceeds the threshold for a certain period of time.

(1 trip detection logic)

Battery ECU assembly

Comes on

Master Warning Light:

Comes on

MONITOR DESCRIPTION

The battery ECU assembly monitors the hybrid vehicle control ECU via CAN communication. If the battery ECU assembly detects a malfunction in the hybrid vehicle control ECU, it will illuminate the MIL and store a DTC.

MONITOR STRATEGY

Related DTCs

P0A1F (INF P0A1F94): Battery Energy Control Module

Required sensors/components

Battery ECU assembly

Frequency of operation

Continuous

Duration

TMC's intellectual property

MIL operation

1 driving cycle

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not stored

TMC's intellectual property

Other conditions belong to TMC's intellectual property

-

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property

-

COMPONENT OPERATING RANGE

Hybrid vehicle control ECU

P0A1F (INF P0A1F94) is not detected

CONFIRMATION DRIVING PATTERN

HINT:

  • After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

    Click here

  • When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.

    Click here

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 2 minutes or more.
  5. Turn the power switch on (IG) and turn the Techstream on.
  6. Turn the power switch on (READY) and wait for 10 seconds or more. [*1]

    HINT:

    [*1] : Normal judgment procedure.

    The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.

  7. Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
  8. Check the DTC judgment result.

    HINT:

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.

PROCEDURE

1.

CHECK DTC OUTPUT (HYBRID CONTROL)

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

(d) Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes

Result

Proceed to

P0A1F94 only is output.

A

DTCs except P0A1F94 are output.

B

(e) Turn the power switch off.

A

REPLACE BATTERY ECU ASSEMBLY

B

GO TO DTC CHART (HYBRID CONTROL SYSTEM)

READ NEXT:

 Drive Motor "A" Temperature Sensor Circuit Short to Ground (P0A2A11,P0A2A15)

DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs are stored when the motor temperature sensor output is abnormal. The cause of this malfunction may be one of the following: Hybrid vehicle control ECU m

 Drive Motor "A" Temperature Sensor Voltage Out of Range (P0A2A1C,P0A2A1F)

DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs are stored when the motor temperature sensor output is abnormal. The cause of this malfunction may be one of the following: Motor temperature sensor mal

 Generator Temperature Sensor Voltage Out of Range (P0A361C,P0A361F)

DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs are stored when the generator temperature sensor output is abnormal. The cause of this malfunction may be one of the following: Generator temperature se

SEE MORE:

 Other interior features

Sun visors To set the visor in the forward position, flip it down. To set the visor in the side position, flip down, unhook, and swing it to the side. To use the side extender, place the visor in the side position, then slide it backward. Vanity mirrors Slide the cover to ope

 Switch Failure (B2342)

DESCRIPTION This DTC is stored when the sliding roof ECU (sliding roof drive gear sub-assembly) detects that the sliding roof switch (map light sub-assembly) is stuck for 30 seconds or more. DTC No. Detection Item DTC Detection Condition Trouble Area B2342 Switch Failure Sliding roo

© 2016-2024 Copyright www.lexguide.net