DESCRIPTION
If the motor generator control ECU, which is built into in the inverter with converter assembly, is reset due to a problem with the power source in the inverter, the motor generator control ECU will store this DTC.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
---|---|---|---|---|---|
P0A1B1F | Generator Control Module Circuit Intermittent | Error in reset signal from the inverter assembly power source IC: If internal power source voltage drops below the normal CPU operating voltage or the ROM/RAM is malfunctioning, the power source IC resets the MG ECU and stores this DTC. (1 trip detection logic) |
| Comes on | Master Warning Light: Comes on |
MONITOR DESCRIPTION
The motor generator control ECU monitors its internal operation and will illuminate the MIL and store a DTC if it detects a malfunction.
MONITOR STRATEGY
Related DTCs | P0A1B (INF P0A1B1F): Drive Motor "A" Control Module |
Required sensors/components | Motor generator control ECU |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | Immediately |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored | TMC's intellectual property |
Other conditions belong to TMC's intellectual property | - |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0A1B (INF P0A1B1F) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
Click here
Click here
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
HINT:
WIRING DIAGRAM
CAUTION / NOTICE / HINT
CAUTION:
Click here
HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a | Without waiting for 10 minutes |
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
PROCEDURE
1. | CHECK DTC OUTPUT |
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble Codes Result | Proceed to |
---|---|
P0A1B1F only is output. | A |
DTCs of hybrid control system in the tables below are output. | B |
DTCs of motor generator control system in the tables below are output. | C |
Malfunction Content | System | Relevant DTC | |
---|---|---|---|
Communication malfunction | Motor generator control system | P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message |
Hybrid control system | P312387 | Lost Communication with Missing Message | |
U011087 | Lost Communication with Drive Motor Control Module "A" Missing Message |
(e) Turn the power switch off.
B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
C | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
2. | CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
Result | Proceed to |
---|---|
OK | A |
NG (The connector is not connected securely.) | B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
B | CONNECT SECURELY |
C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
3. | CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM) |
(a) Check the connection of the auxiliary battery terminal.
OK:
The terminal is connected securely and there is no contact problem.
NG | CONNECT SECURELY |
|
4. | CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY) |
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the A58 inverter with converter assembly connector.
(c) Remove the IGCT relay from the No.3 relay block.
(d) Measure the resistance according to the value(s) in the table below.
*1 | No.3 Relay Block | *2 | IGCT Relay |
*a | Front view of wire harness connector (to Inverter with Converter Assembly) | - | - |
Standard Resistance:
Tester Connection | Condition | Specified Condition |
---|---|---|
A58-6 (+B) - 5 (IGCT relay) | Power switch off | Below 1 Ω |
A58-5 (+B2) - 5 (IGCT relay) | Power switch off | Below 1 Ω |
A58-24 (GND1) - Body ground | Power switch off | Below 1 Ω |
A58-23 (GND2) - Body ground | Power switch off | Below 1 Ω |
(e) Install the IGCT relay.
(f) Reconnect the A58 inverter with converter assembly connector.
NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
5. | CHECK FOR INTERMITTENT PROBLEMS |
(a) Check for intermittent problems.
Click here
(1) Check the connection and terminal contact pressure of the connectors and wire harnesses between the auxiliary battery and the inverter with converter assembly.
There are no abnormalities in the wire harnesses and connectors.
OK | REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS |
NG | REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA |