Lexus ES: Diagnosis System
DIAGNOSIS SYSTEM
DLC3 (Data Link Connector 3)
(a) Check the DLC3.
Click here
AUXILIARY BATTERY VOLTAGE
Standard Voltage:
Switch Condition | Specified Condition |
Power switch on (IG) | 11 to 14 V |
-
If voltage is below 11 V, recharge or replace the auxiliary battery.
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
READ NEXT:
DTC CHECK / CLEAR CHECK FOR DTCS (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Powertrain / Hybrid Control / Tro
TERMINALS OF ECU *a Hybrid Vehicle Control ECU - - HINT: The standard normal voltage between each pair of hybrid vehicle control ECU terminals is shown in the table below. The appropriate
PROCEDURE 1. VEHICLE BROUGHT TO WORKSHOP
NEXT 2. CONFIRM PROBLEM SYMPTOMS
NEXT 3. CUSTOMER PROBLEM ANALYSIS (a) Check if the vehicle has be
SEE MORE:
The SRS airbags inflate when the vehicle is subjected to certain types
of severe
impacts that may cause significant injury to the occupants. They work together
with the seat belts to help reduce the risk of death or serious injury.
SRS airbag system
■ Location of the SRS airbags
SRS front
DESCRIPTION If the battery voltage sensor detects an internal malfunction, it sends an error signal to the hybrid vehicle control ECU. When the hybrid vehicle control ECU receives the error signal from the battery voltage sensor, the ECU warns the driver and performs fail-safe control. DTC No.