Lexus ES manuals

Lexus ES: Inspection

INSPECTION

PROCEDURE

1. INSPECT FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

20°C (68°F)

22 to 28 Ω

If the result is not as specified, replace the flow shutting valve (water by-pass hose assembly).

READ NEXT:

 Installation

INSTALLATION PROCEDURE 1. INSTALL FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY) (a) Connect the flow shutting valve (water by-pass hose assembly) to the transmission oil cooler and slide the clip

 Radiator

 Components

COMPONENTS ILLUSTRATION *1 FRONT WHEEL OPENING EXTENSION PAD LH *2 FRONT WHEEL OPENING EXTENSION PAD RH *3 NO. 1 ENGINE UNDER COVER *4 NO. 2 ENGINE UNDER COVER ASSEMBLY N*m

SEE MORE:

 Removal

REMOVAL CAUTION / NOTICE / HINT The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during power window regulator motor assembly removal/installation are shown below. Necessary Procedure After P

 Power Trunk Lid does not Operate Using Any Switches

DESCRIPTION The power trunk lid controls the luggage closer motor assembly and operates the luggage closer motor assembly and luggage door closer assembly. If the power trunk lid does not operate using any of the operations, a malfunction related to the power trunk lid operation conditions or luggag

© 2016-2025 Copyright www.lexguide.net