Lexus ES manuals

Lexus ES: Data List / Active Test

DATA LIST / ACTIVE TEST

ACTIVE TEST

HINT:

Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG). (for HV Model)

(c) Turn the engine switch on (IG). (for Gasoline Model)

(d) Turn the Techstream on.

(e) Enter the following menus: Body Electrical / Main Body / Active Test.

(f) Perform the Active Test according to the display on the Techstream.

Body Electrical > Main Body > Active Test

Tester Display

Measurement Item

Control Range

Diagnostic Note

Vehicle Horn

Vehicle horn

OFF / ON

-

READ NEXT:

 Relay

On-vehicle InspectionON-VEHICLE INSPECTION PROCEDURE 1. INSPECT HORN RELAY *a Component without harness connected (HORN Relay) (a) Measure the resistance according to the value(s) in the tab

 Lighting (ext)

 Automatic Light Control Sensor

ComponentsCOMPONENTS ILLUSTRATION *1 AUTOMATIC LIGHT CONTROL SENSOR *2 NO. 1 SPEAKER OPENING COVER ASSEMBLY On-vehicle InspectionON-VEHICLE INSPECTION PROCEDURE 1. INSPECT AUTOMATIC LIG

SEE MORE:

 Removal

REMOVAL PROCEDURE 1. REMOVE FRONT DOOR SCUFF PLATE LH Click here 2. REMOVE COWL SIDE TRIM BOARD LH Click here 3. REMOVE FRONT DOOR OPENING TRIM COVER LH Click here 4. REMOVE INSTRUMENT SIDE PANEL LH Click here 5. REMOVE NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY Click here 6. REMOVE L

 Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold (P0D2D16,P0D2D17,P0D2D1F)

DESCRIPTION The inverter contains a three-phase bridge circuit, which consists of 6 power transistors (IGBTs) each for the generator (MG1) and motor (MG2). The inverter converts high-voltage direct current from the HV battery into three-phase alternating current for the generator (MG1) and motor (MG