Lexus ES: Customize Parameters
CUSTOMIZE PARAMETERS
CUSTOMIZING WITH REMOTE TOUCH (REMOTE OPERATION CONTROLLER ASSEMBLY)
(a) Customizing with the touch function cancellation function. (w/ Touch Function Cancellation Function)
NOTICE:
Confirm the touchpad surface is free of foreign matter before customizing.
(1) Turn the power switch on (ACC).
(2) Simultaneously press and hold the "MAP" switch and back switch for 5 seconds or more.
*a | "MAP" Switch |
*b | Back Switch |
(3) While pressing and holding the "MAP" switch and back switch, tap the touchpad with 2 fingers.
HINT:
-
If any switch other than the "MAP" switch or back switch is pressed, the customize setting cannot be changed.
-
Do not pinch in/out or slide fingers when tapping the touchpad with 2 fingers.
(4) Confirm that the answer-back function vibrates the touchpad a specified number of times to indicate that the setting has changed.
Setting
Touch Function Cancellation Function | Number of Answer Back Vibrations |
Off (Default) | 1 |
On | 2 |
(5) Repeat step (3) until the desired setting is selected.
HINT:
The touch function cancellation function alternates between on and off.
(6) Release the "MAP" switch and back switch to select the set value.
READ NEXT:
DATA LIST / ACTIVE TEST DATA LIST NOTICE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a pa
DESCRIPTION The No. 1 stereo jack adapter assembly sends the sound data signal or image data signal from a USB device to the radio receiver assembly via this circuit. WIRING DIAGRAM PROCEDURE 1.
DIAGNOSTIC TROUBLE CODE CHART Navigation System DTC No. Detection Item Link B1323 Lost Communication with Haptic Device B1324 Lost Communication with Meter B1325 Los
SEE MORE:
You can view the status of your
hybrid system and fuel consumption
information on the multi-information
display and Center Display.
12.3-inch display model: The
energy monitor or consumption
screen can be displayed on the side
display.
System components
Multi-information display
Ce
INSPECTION PROCEDURE 1. INSPECT CONNECTING ROD THRUST CLEARANCE (a) Install the connecting rod cap. Click here (b) Using a dial indicator, measure the thrust clearance while moving the connecting rod back and forth. Standard Thrust Clearance: 0.15 to 0.40 mm (0.00591 to 0.0157 in.) Maximum Thr
© 2016-2025 Copyright www.lexguide.net