Lexus ES: Customize Parameters
CUSTOMIZE PARAMETERS
CUSTOMIZE POWER MIRROR CONTROL SYSTEM (w/ Memory)
NOTICE:
-
When the customer requests a change in a function, first make sure that the function can be customized.
-
Record the current settings before customizing.
HINT:
The following items can be customized.
(a) Customizing with the Techstream
(1) Connect the Techstream to the DLC3.
(2) Turn the power switch on (IG).
(3) Turn the Techstream on.
(4) Enter the following menus: Customize Setting / Others.
(5) Select the setting by referring to the table below.
Others
Tester Display | Description | Default | Setting | ECU |
Auto Fold Mirror | Function that changes the condition under which the outer mirrors automatically retract | Door Lock | 01:ACC,10:Door Lock,11:OFF | Main body ECU (Multiplex network body ECU) |
Reverse Coupled Actuation Mirror Angle | Function that turns the reverse shift-linked mirror position memorization function on or off | User Setting | 0:Default Setting,1:User Setting | Main body ECU (Multiplex network body ECU) |
READ NEXT:
PROBLEM SYMPTOMS TABLE HINT:
Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of
TERMINALS OF ECU CHECK OUTER MIRROR CONTROL ECU ASSEMBLY (DRIVER DOOR) (a) Disconnect the J28 outer mirror control ECU assembly (driver door) connector. (b) Measure the voltage and resistance accordi
DIAGNOSIS SYSTEM CHECK DLC3 (a) Check the DLC3. Click here INSPECT AUXILIARY BATTERY VOLTAGE (a) Measure the auxiliary battery voltage with the power switch off. Standard Voltage: 11 to 14 V If the
SEE MORE:
DESCRIPTION The ATF temperature sensor converts the automatic transaxle fluid (ATF) temperature into a resistance value for use by the ECM. The ECM applies a voltage to the temperature sensor through terminal THO1 of the ECM. The sensor resistance changes with the ATF temperature. As the temperature
DESCRIPTION The cause of this malfunction may be the generator high-voltage circuit. Check the generator internal resistance and the connection condition of the high-voltage line between the inverter and generator to check whether there is an open or short circuit. Related Parts Check Area Insp